Capital Controls' Series 1870E chlorine residual analyzer technology has been independently tested and proven to be a reliable analyzer for continuous, accurate residual analysis. The amperometric-based instrument is designed to continuously analyze free or total chlorine, chlorine dioxide, potassium permanganate, iodine, bromine or other oxidants for water, wastewater, cooling water and other process water applications. Series 1870E features a field selectable monitoring range from 0-0.1 to 0-20 mg/l. the analyzers incorporate a constant, direct-drive electrode cleaning system which eliminates signal drift and the need for frequent recalibration. Internal high and low set points are sstandard. The analyzer's reagent and sample are gravity fed eliminating the need for metering pumps. Extra large gold and copper electrodes are used for maximum signal strength. Sample temperature variations are compensated within the measuring cell, thereby providing consistent residual values. |
Applications
|
Design Features
|
Principle
of Operation A sample liquid is delivered to the constant head weir at an approximate rate of 500 ml/minute. The excess overflows to drain. The sample then passes through the annular space between the two fixed electrodes in the sensing cell. As it passes, a small DC current is generated in direct linear proportion to the amount of residual present in the sample. The residual value is displayed on the digital indicator in mg/l. The surfaces of both electrodes are kept clean by the continuous action of PVC spheres agitated by a motor-driven rotating striker. This constant cleaning eliminates signal drift and recalibration, and provides an accurate residual measurement. A thermistor compensates for sample temperature variatioon. The liquid reagent is stored in a single bottle an fed from constant head reservoir through a rotary valve. This configuration adds the precise amount of solution during each valve rotation. The reagent bottle supplies 7 days of use before refilling is required. An optional reagent feed system may be adapted for pH buffering using carbon dioxide gas for water treatment applications. |
| Specifications Instrument Range: Field selectable 0-0.1, 0-0.2, 0-0.3, 0-0.5, 0-1, 0-2, 0-3, 0-5, 0-10, 0-20 (mg/l) (Others available, consult factory) Resolutions: 0.001 mg/l (1 ppb) Power Requirements: 120 Vac, 60 Hz, or 240 Vac, 50 Hz, single phase Output Signal: Isolated 4-20 or 0-20 mAdc into a maximum of 800 ohms or 0-50 mVdc. Sample Flow: 500 ml/minute Sample Temperature Range: 32° to 120° F (0° to 50°C) |
Speed of Response:
4 seconds from sample entry to display indication. 90% of full scale response within 1 1/2
to 2 minutes Ambient Temperature: 32° F to 120° F (0° C to 50° C) Sample Limitations: Samples containing high concentrations of metal ions or certain corrosion inhibitors may effect analyzer operation. At low residual levels (less than 0.1 mg/l) variations in sample dissolved oxygen level may affect the residual reading. Consult factory for specific applications. Accuracy: 0.003 mg/l or +/-1% of range whichever is larger. |
Reagent Requirement
Shipping Weight: 14 lbs. (6.4 kgs) |

|
|
| Profile | Main Activities | Products | Contact Us | |
|
Comments and questions:
ccipl@giasbm01.vsnl.net.in.
URL: http://www.capitalcontrolsindia.com ![]()
Copyright © 1989 - 2009 Capital Control India Pvt. Ltd. Disclaimer
These site has been designed & is maintained by TRRYST
TECHNOLOGY.
Comments and Suggestions to the Web
Master : ![]()